B-Bonds, Double Stud | | B-Bonds, Single Stud | | RS B-Bond, Pedestals | | Double RS B-Bond, for Splice Cases | | RS B-Bond for NIDs | | B-Bond with Short Stud/Harness | | TS Cable Shield Connector w/Harness | | U-Shaped BSW Shield Connectors - Intro | | U-Shaped BSW, Floating | | U-Shaped BSW, w/Screw | | U-Shaped Pedestal BSW, w/Teeth | | U-Shaped Pedestal BSW, #6, Floating | | Short U-Shaped BSW, Floating | | Long U-Shaped BSW, Floating | | Short U-Shaped BSW, Rigid | | Medium U-Shaped BSW | | Medium U-Shaped BSW, Aluminum Shield | | Long U-Shaped BSW, Peds | | Larger Diameter U-Shaped BSW | | BARP Series - Spark Gap Shield Termination | | Optional Accessories | | BSW Floating Bond | | Bow Ties | | Rocket 88 | | Rocket 88 w/Leads | | Rocket 88 Accessories | | Extra Large Shield Connector for 25-pair CAT5 Cable | | Shielded Aerial Service Wire Bond Kit | | Shielded Aerial Service Wire Bond Kit, NIDs | | Shielded Aerial Service Wire Connector | | Shielded Aerial Service Wire Ground Kit | | Shield Connector for T1 Cable | | Bonding Coin | | Bonding Stud Coin | | EMC/Griplok | | Hole Punch Tool w/Adjustable Gauge | | Hole Punch Tool | | Double Hole Punch Tool | | G Protector Clips | | Conduit Ground | | Zinc Split Bolt Connector | |
|
 |

|
 |
B-Bonds, Double Stud
Features
- Tin-plated bronze and copper construction for high
conductivity.
- 3/8" nuts fit standard terminal wrench.
- Piercings in bottom plate penetrate Mylar lining on inner
surface of shield.
- Can be used with or without punching holes in
sheath.
- When cable shield is tabbed and punched, one size works on
all cables.
- Two studs prevent loosening of connections due to
counter-clockwise movement of bond strap.
- Two studs offer lower resistance and higher
current-carrying capacity. This enables use of a smaller size shield
connector.
- Two studs offer higher pullout strength.
Clamps on this page are available with torque shear head nuts, which break off at proper installation torque. Add suffix -TSH.
For optional flat plastic pair saver, add suffix -P.
 For optional pair saver molded to bottom plate, add suffix -MP.
|
|
Ordering Information

EM 2BBM Double stud with double nut per stud, for up to .5" cable.


EM 2BB1 Double stud with double nut per stud, for .5"–.8" cable.

EM 2BB2 Double stud with double nut per stud, for .8"–1.6" cable.

EM 2BB3 Double stud with double nut per stud, for 1.6" cable and up.

EM 1BBM Double stud with single nut per stud, for up to .5" cable.


EM 1BB1 Double stud with single nut per stud, for .5"–.8" cable.

EM 1BB2 Double stud with single nut per stud, for .8"–1.6" cable.

EM 1BB3 Double stud with single nut per stud, for 1.6" cable and up.

EM PSAVER Optional flat plastic pair saver, supplied as a loose piece.


|
 |
  |